The PHG-11TT-*8+ thermocouple input temperature converter with surge protection function can transmit the millivolt signal from thermocouple (TC) and output in 1: 1.
This product requires independent power supply, with isolated power supply, input, and output terminals.
"*" represents the input type of the thermocouple, and the specific model is represented by a code (see "Input Signal Type and Range Table" for details).
Input signal types and measurement range | ||||
Code | TC model | Measurement range | Minimum range | Conversion accuracy |
1 | K | -200~1370ºC | 50ºC | 0.5ºC/0.1% |
2 | S | -50~1760ºC | 500ºC | 1.5ºC/0.1% |
3 | E | -140~1000ºC | 50ºC | 0.5ºC/0.1% |
4 | J | -160~1200ºC | 50ºC | 0.5ºC/0.1% |
5 | B | 250~1800ºC | 500ºC | 1.5ºC/0.1% |
6 | T | -200~400ºC | 50ºC | 0.5ºC/0.1% |
7 | R | -50~1760ºC | 500ºC | 1.5ºC/0.1% |
8 | N | -200~1300ºC | 50ºC | 0.5ºC/0.1% |
For example: one input and one output, thermocouple K (-200~1370C) input, one channel 1:1 output, 24V power supply, model: PHG-11TT-18
Specifications
Input | |
Input signal | K, S, E, J, B, T, R, N thermocouple signals (see "Input Signal Type and Range Table" for details) |
Signal range | The measuring range of the corresponding thermocouple is -5~60mV. |
Safety side output: | |
Output signal | Thermocouple 1: 1 |
Surge protection features: | |
Nominal discharge current ln(8/20μs) | 5kA |
Voltage protection level Up(8/20μs): | 60V(line to line) |
Voltage protection level Up(8/20μs): | 600V(line to ground) |
According to standards | GB/T18802.21-2016(equivalent to 1EC61643-21:2012) |
Power consumption | <0.8W (24VDC power supply, 20mA output) |
LED indicator | Green: Power indicator |
Output accuracy | Please refer to the "Input Signal Type and Range Table" for details |
Response time | Reaching 90% of the final value within 300ms |
Temperature drift | 0.005%F.S/ºC |
Temperature parameters | Working temperature: -20ºC~+60ºC, storage temperature:-40ºC~+80ºC |
Relative humidity | 10%~95% RH no condensation |
Insulation strength | ≥2000VAC/min (between input/output/power supply) |
Insulation resistance | 100MΩ(500V DC) (between input/output/power supply) |
Electromagnetic compatibility | According to IEC 61326-1(GB/T 18268), IEC 61326-3-1 |
MTBF | 80000h |
Wire requirements | Horizontal cutting surface ≥ 0.5mm2; Insulation strength ≥ 500V |
Applicable field equipments | K. S, E, J, B, T, R, N TC sensors |
Installation place | Installed in a safe zone, it can be connected to intrinsic safety instruments in hazardous areas up to Zone 0, IIC, Zone 20, and IIIC |