Hazardous Area Switch Contacts Proximity Switches Safety Barrier Isolation

Task: Adjust
Structure: Combination
Signal: Discrete
Function: Automatic Control
Certification: RoHS, CCC, ISO: 9001, CE
Condition: New
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
PHD-11HF-2828
Customized
Non-Customized
Transport Package
Box
Specification
Thickness 15.8mm * width 104.8mm * high 116.1mm
Trademark
Beijing Pinghe
Origin
Beijing
Production Capacity
30000/Month

Product Description

Hazardous Area Switch Contacts Proximity Switches Safety Barrier IsolationOverview

The base plate mounted isolated safety barrier PHD-11HF-2828 transmits the input signals from switch contacts or proximity switches in the hazardous area to the safe area transistor outputs via the safety barrier isolation. Line fault detection is via a separate relay output (optional) and is indicated by an LED on the top of the module. Switches on the module are used to select the phase of the channel and whether the line fault detection function is required.

The product requires a separate power supply with triple isolation for power, input and output.

Line Fault Detection (LFD)

Line Fault Detection (LFD) is a user-selectable switch on the top of the module and is indicated by an LED. If a line fault is detected, the line fault relay is closed and the channel output relay is disconnected. Short circuit alarm (SC) for field input current >7mA; open circuit alarm (LB) for field input current <0.1mA; switch contact input; 22kΩ resistor must be connected in parallel at both ends of the switch for line fault detection (e.g., switch contact II in the wiring diagram).

 

 

Main technical parameters

 

 

Number of channels: two inputs and two outputs
Power supply:
Power supply voltage: 20~35V DC, power consumption of about 1W (24V DC, output 20mA)
Power protection: power reverse protection
Hazardous side input:
Input signal: switch contact/proximity switch
Sensor supply voltage: approx. 8V
Input/Output Characteristics:
Field input current: When >2.1mA, the output is closed, indicating ON; When <1.2mA, the output is open, indicating OFF.
Output e-c on/off state switching control: DIP switches K1, K3 set to "ON" side,  the transistor output e-c is on.
DIP switch K1, K3 set to "OFF" side, transistor output e-c cutoff.
DIP switch K2, K4 set to "ON" side, the circuit selects the indicator light red LFD alarm function.
Safety side output:
Output signal: transistor, alarm relay (optional)
Driving capacity: output current ≤ 20mA (1.2kΩ), the maximum internal current of 100mA, a short-circuit current protection
Output characteristics: NPN transistor emitter or open collector output
LED indicator: green power indication; yellow output transistor normal working status; red LFD indication, line failure alarm
Temperature parameters: operating temperature -20ºC~+60ºC; storage temperature -40ºC~+80ºC
Air relative humidity: 10%~95%RH without condensation
Insulation strength: intrinsically safe end and non-intrinsically safe end (≥3000V AC/min); between power supply and non-intrinsically safe (≥1500V AC/min)
Insulation resistance: ≥100MΩ (input/output/power supply between)
Electromagnetic compatibility: in line with IEC 61326-1 (GB/T 18268), IEC 61326-3-1
Mean time to failure: 100000 hours
Wire requirements: cross-section ≥ 0.5mm2; insulation strength ≥ 500V
Applicable field devices: dry contact or NAMUR type proximity switch inputs according to DIN19234, etc.
Installation site: installed in the safe zone, can be connected with the highest in Zone 0, IIC, Zone 20, IIIC hazardous locations of the intrinsically safe instrumentation
Safety certification
Certification body: National Explosion-proof Electrical Product Quality Supervision and Testing Center CQST
Certification standard: GB/T 3836.1-2021, GB/T 3836.4-2021
Explosion-proof symbol: [Exia Ga]IIC, [Exia Da]IIIC
Certified parameters (between terminals 1-2): Um: 250V AC/DC, Uo=10.5V DC, Io=15mA, Po=39.4W, Co=1.7μF, Lo=165mH.
 

Hazardous Area Switch Contacts Proximity Switches Safety Barrier Isolation

Hazardous Area Switch Contacts Proximity Switches Safety Barrier IsolationHazardous Area Switch Contacts Proximity Switches Safety Barrier IsolationHazardous Area Switch Contacts Proximity Switches Safety Barrier IsolationHazardous Area Switch Contacts Proximity Switches Safety Barrier Isolation

Hazardous Area Switch Contacts Proximity Switches Safety Barrier Isolation
Q:Do you accept OEM or ODM orders?

A: Yes.we do.Please let us know your requirements

 

Q: What is your MoQ?

A:No MOQ limits.1 piece for trial order at first is acceptable

 

Q:What is your warranty for your product?

A:2 years (2 years maintenance guaranteed for non-man-made damages)

 

Q: How do you assure the quality?

A: Attaching great importance to quality control,we check every step to make sure items in good quality.

Hazardous Area Switch Contacts Proximity Switches Safety Barrier Isolation
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
63
Year of Establishment
2004-01-13