Surge protection switch input transistor output signal isolator converts the input signal of the switch contact or proximity switch into a transistor output through isolation.
Line fault detection is output through a separate relay and displayed by an LED light on the top of the module. The switch of the module is used to select the phase of the channel and whether the line fault detection function is required.
This product needs to be powered independently, and the power supply, input and output terminals are isolated.
Specifications
Input | |
Input signal | Switch contacts/proximity switches |
The supply voltage of the sensor | About 8V |
Input frequency range | ≤5kHz |
Input/output characteristics: | |
On site input current | >2.1mA, the output is closed, indicating ON; When<1.2mA, the output is open circuit, indicating OFF |
Switched control between inverted phase and normal phase of outputs e-c | When the dial switch K1,K3 is at "ON", the transistor output e-c are in inverted phase When the dial switch K1,K3 is at "OFF", the transistor output e-c are in normal phase When the K2,K4 is at "ON", the circut will select the red light LFD indication alarm function |
Output | |
Output signal | Transistor |
Drive capacity | Output current ≤20mA (1.2kΩ), internal maximum current 100mA, equipped with short-circuit current protection |
Surge protection features: | |
Nominal discharge current ln(8/20μs) | 5kA |
Voltage protection level Up(8/20μs): | 60V(line to line) |
Voltage protection level Up(8/20μs): | 600V(line to ground) |
According to standards | GB/T18802.21-2016(equivalent to 1EC61643-21:2012) |
Basic parameters | |
Supply voltage | 20~35VDC |
Power consumption | <1.2 W(24V power supply, when the transistor are in inverted phase) |
LED indicator | Green: Power indicator Yellow: Output transistor in normal working state Red: LFD indication, line fault alarm |
Temperature parameters | Working temperature: -20ºC ~ +60ºC, Storage temperature: -40ºC ~ +80ºC |
Relative humidity | 10%~95% RH no condensation |
Insulation strength | ≥2000VAC/min (between input/output/power supply) |
Insulation resistance | 100MΩ(500V DC) (between input/output/power supply) |
Electromagnetic compatibility | GB/T 18268 (IEC 61326-1) |
MTBF | 80000h |
Wire requirements | Horizontal cutting surface ≥ 0.5mm2; Insulation strength ≥ 500V |
Applicable field equipments | Field equipment such as dry contacts or NAMUR type proximity switch inputs that comply with DIN19234 standard |